• Do not scrape off stubborn dirt using hard objects.
• Do not use any sharp-edged tools.
• Soften paper stickers in advance for easy removal.
Cleaning the charging cable
• Only clean the charging cable when it is not connected.
• Clean the charging cable and dirty contacts with a dry cloth.
• Never immerse the charging cable and charging plug in liquids.
10.5

UC 100 maintenance

10.5.1

Replacing an air filter

The air filters of the charging station remove the dust from the outside air pulled in for cooling
the interior. With increasing operating time, the filtered dust particles reduce the air flow
through the filters. The reduced airflow cools the interior of the charging station less. This causes
the temperature inside the charging station to rise.
To keep the air inside the charging station within the permitted temperature range, regularly
replace the fabric filters of the cabinet fans.
Required tools and spare parts
You will need the following tools to replace an air filter:
• Screwdriver
• Bit: Hexagon socket, SW6
You will also need the following spare part:
• Fabric filter: Filter class G3 according to standard EN 779
SICHARGE UC 100, UC 200, UC 300, UC 400, UC 600, UC 800
Operating Instructions, 10/2022, A5E50828019-AC
Position
Front
Left and right side
Rear
Maintenance and service
10.5 UC 100 maintenance
Dimensions
630 x 105 x 60 mm
830 x 105 x 35 mm
630 x 105 x 35 mm