3.3 Description of UC 300/400
Temperature monitoring
The integrated temperature monitoring of the charging cable ensures safe transfer of the
charging power. Temperature sensors monitor the charging contacts DC+ and DC- during the
entire charging process. If the temperature at one of the charging contacts rises above 90 °C, the
charge control system switches off the power supply to the charging cable immediately and
safely.
Performance features
The charging cable has the following features:
Feature
Charging standard
Charging mode
Rated current
Rated voltage
Cable outer diameter
Permissible ambient temperature in operation
Power contacts
Insertion cycles
Insertion and withdrawal force
Degree of protection with an inserted charging plug IP44
Degree of protection with a charging plug not in‐
serted
3.3

Description of UC 300/400

3.3.1

Product overview

The SICHARGE UC 300/400 charging station enables high-performance charging of electric
vehicles. Thanks to the support of the open, universal charging standard CCS Combo 2, the
station charges different vehicle models from different manufacturers quickly and efficiently.
Performance features
The SICHARGE UC 300/400 charging station charges your electric vehicle quickly and safely. The
charging station controls the entire charging process fully automatically and accurately.
The charging station features the following performance characteristics:
• Fully automatic control of the charging process
• User-friendly operation by a central touch screen
• Space-saving construction
32
Value
IEC 62196-3
4
200 A
1000 V DC
32.0 mm ± 0.2 mm
-30 °C ... +50 °C
DC+, DC-, PE
> 10000
< 100 N
IP20
SICHARGE UC 100, UC 200, UC 300, UC 400, UC 600, UC 800