Pull the Ethernet cable through the opening in the bottom of the cabinet
If you are installing a charging station for charging via distributed charging points, pull the
Ethernet cable through the opening in the base of the charging station cabinet.
 Only applies to equipment variants of the charging station that are set up for SICHARGE UC
1)
Dispenser, SICHARGE MastHood, or SICHARGE MastPanto.
Pull the auxiliary power supply cable through the opening in the bottom of the cabinet
If you are installing a charging station for charging via decentralized charging points, pull the
auxiliary power supply cable through the opening in the base of the charging station cabinet.
 Only applies to equipment variants of the charging station that are set up for SICHARGE UC
1)
Dispenser, SICHARGE MastHood, or SICHARGE MastPanto.
Reposition the charging station on the base area
1. Close the cabinet door.
2. Drive the forks of the forklift from the front or from behind under the bottom of the cabinet.
3. Lift the charging station vertically upwards.
4. Remove the wooden beams.
5. Lower the charging station onto the base area.
Guiding the cables through the cable glands
1. Guide all cables used through the cable glands of the cable gland plate.
2. Slide the cable gland plate to the cutout from which it was removed.
3. Screw the cable gland plate to the cabinet with the four fastening screws.
4. Tighten the cable glands on the cables.
5.4.2

Securing the charging station

After inserting the power cord into the cabinet, attach the charging station to the base area.
Required tools and fasteners
You will need the following tools to secure the charging station:
• Torque wrench
• Socket: Hexagon, SW18
SICHARGE UC 100, UC 200, UC 300, UC 400, UC 600, UC 800
Operating Instructions, 10/2022, A5E50828019-AC
Mounting
5.4 Installation of UC 200
1
1
77