Bumper
To protect the charging station against contact by vehicles, install a bumper
Figure 4-11
Plan for bumpers based on the dimensions of the vehicles used. The bumper must stop the
vehicle before the vehicle overhang touches the charging station
interfere with the opening of the charging station's cabinet door.
4.3.2

Preparing the base area

In order to secure the charging station securely on the intended base area, you need to prepare
the base area.
Example of foundation
Make a static calculation for the base area to ensure stability. This calculation must include the
following factors, among others:
• Ground survey
• Wind load
• Snow load
• Earthquakes
The dimensions and design of the foundation are determined by the static calculation. The
figure below shows a schematic example of the design of the foundation made of reinforced
SICHARGE UC 100, UC 200, UC 300, UC 400, UC 600, UC 800
Operating Instructions, 10/2022, A5E50828019-AC
Bumper
Safety clearance
Charging station
Example: Correct position of the bumper and charging station
Application planning
4.3 Application planning of UC 200
.
. The bumper must not
55