Securing the charging station in a raised position
To insert the power cable into the cabinet, you need to first lift the charging station and fix it in
a raised position:
1. Drive the forks of the forklift from the front or from behind under the bottom of the cabinet.
2. Lift the charging station vertically upwards.
3. Position one wooden beam under each of the cabinet feet.
Figure 5-3
4. Lower the charging station onto the wooden beams.
Remove the protective cover
To make the cable gland accessible, first remove the lowest protective cover inside the charging
station:
1. Open the cabinet door.
2. Remove the handle of the main switch.
3. Unscrew the fastening screws of the lowest protective cover.
4. Remove the protective cover.
SICHARGE UC 100, UC 200, UC 300, UC 400, UC 600, UC 800
Operating Instructions, 10/2022, A5E50828019-AC
Wooden beam
Charging station in raised position
Mounting
5.4 Installation of UC 200
75