6.4 Replacement of wireless router or modem 6.5 Not connected to the OCPP server, not reporting software firmware version/serial number 6.6 Charger offline/not connected to the VersiCharge SG cloud 6.7 Diagnostics file download feature Section 7: VersiCharge cloud connection troubleshooting...
1.1 Read this First This manual contains important instructions for use during installation, operation and maintenance of the Siemens VersiCharge SG™ electric vehicle (EV) charging station. 1.2 Symbol Legend The following safety symbols indicate dangerous conditions and important safety instructions and appear throughout this document to reduce the risk of electrical shock, ensure the safe installation and operation of the Siemens VersiCharge SG.
The owner of a VersiCharge SG unit can cancel or opt out of any utility event, if this is not defined differently in the specifications of the utility program. The user should be aware of any increase in cost or disqualification from the utility programs specified by the utility, as a result of canceling or opting out events.
VersiCharge™ SG Commissioning and Troubleshooting Guide 1.6 Instructions pertaining to a risk of fire or electric shock WARNING! When using electric products, basic precautions should always be followed, including the following. Note: This manual contains important instructions for the Universal Unit that shall be followed during installation, operation, and maintenance of the unit.
• This device has been designated to meet the requirements in section 626 of the National Electric Code (NEC®). • UL Listing with Listing Number – Siemens VersiCharge Devices are listed in UL file # E348556. • Complies with the following UL Standards: 2594, 2231-1, 2231-2.
VersiCharge™ SG Commissioning and Troubleshooting Guide SECTION 2 Device Layout 2.1 User Interface (UI) Power Pause Charging Zigbee Infrared Service Portal Wi-Fi Status Time Delay Ready Fault 10. Remote Control 11. Remote Control Lock 12. Time Delay Duration (2/4/6/8 hrs) 2.2 UI LED lights and their meaning network strength issue, test your signal strength at the location of your installation.
Commissioning and Troubleshooting Guide VersiCharge™ SG SECTION 3 Faults - General The VersiCharge charger has been designed to self-indicate which type of fault has occurred. A fault is indicated by a solid red halo, a blinking red halo, and/or the fault LED being illuminated. In any of these conditions, press the Pause button twice to reset the device.
Page 10
EV. Adjust the EV settings in order to be compatible with the VersiCharge. Fault– Nuisance. As a leader in electrical technology, Siemens has made the decision to install 5 mA grounding protection in all VersiCharge devices. This is the same level of protection that is required in residential kitchens and bathrooms.
Commissioning and Troubleshooting Guide VersiCharge™ SG SECTION 4 What You Will Need To Troubleshoot • Check that the VersiCharge is plugged in, has power, and the power light is lit. • The URL to access the local web pages is: 1.
Page 12
VersiCharge™ SG Commissioning and Troubleshooting Guide • VersiCharge Cloud URL (https://versichargesg.cloudapp.net) • Ability to test signal strength (Wi-Fi Analyzer for Windows or Network Analyzer for Apple) • Is there a network Extender? For more on the Extender, see Section 5.3. Is the Extender using the same credentials as those set up in the cloud? If not, go into the settings of the Extender and synchronize the credentials.
VersiCharge™ SG Commissioning and Troubleshooting Guide 5.2 Charger not commissioned due to incorrect credentials Charge not commissioned – incorrect credentials Request the customer log into the cloud account. Verify the account is registered. Verify the cloud account login/password information is accurate (be aware that it is case sensitive). Customer cannot log into the cloud account.
Page 15
Commissioning and Troubleshooting Guide VersiCharge™ SG Charge not commissioned - incorrect credentials Select the Submit button once all information has been confirmed; the VersiCharge should communicate with the cloud and be successfully commissioned.
Page 16
VersiCharge™ SG Commissioning and Troubleshooting Guide Charge not commissioned - incorrect credentials Find the MAC address and serial number (Traceability Number) at the bottom of the Commission page. This information will only be available in the cloud account after the VersiCharge has been commissioned and has successfully communicated with the cloud.
Page 17
Commissioning and Troubleshooting Guide VersiCharge™ SG Charge not commissioned - incorrect credentials VersiCharge doesn’t complete commissioning THEN Call Customer Service...
Provide the charger with the correct information set up during account registration to start the second connection attempt to the VersiCharge SG Cloud via the following steps: Enter the information in the Commission web page. Navigate to the System Info section of the Commission page to find the basic information on the charger.
Page 19
Commissioning and Troubleshooting Guide VersiCharge™ SG Check that all credentials for the network have been entered and are correct. Click the Submit button.
Page 20
VersiCharge™ SG Commissioning and Troubleshooting Guide Navigate to the cloud account and check the charger name and IP address; they should appear now. If the charger name/IP address are not in the cloud, Wait several minutes and go back in; this information should appear. This indicates the charger has been success- fully linked and is communicating with the cloud.
Commissioning and Troubleshooting Guide VersiCharge™ SG SECTION 6 Troubleshooting: Post-Commissioning 6.1 Charger unable to communicate to cloud server/service Three conditions may cause this issue: 1. The homeowner’s Internet may be down. 2. The network signal strength is not strong enough for VersiCharge communication. 3. The cloud server/service is down. NOTE: if there has been a password change, allow 24 hours for the password to be synchronized to the VersiCharge.
VersiCharge™ SG Commissioning and Troubleshooting Guide 6.2 Due to wireless network credentials being modified See 5.2, Charger Not Commissioned Due To Incorrect Credentials, with the VersiCharge in AP mode, access the local web pages using http://commission.versichargesg.net 6.3 Due to addition of wireless network extender VersiCharge not communicating due to addition of wireless network extender Navigate to the cloud account and confirm the IP address and MAC address.
Commissioning and Troubleshooting Guide VersiCharge™ SG 6.4 Replacement of wireless router or modem The new router will have to be set up with the VersiCharge and both the Cloud and local webpages need to have the credentials updated. See 6.2 above and update the new router SSID.
The Wi-Fi Module is communicating, and cloud connection is possible. Note: If a new Wi-Fi Module has been provided by Siemens, recommission the VersiCharge by unlinking the charger from the cloud, and follow the commissioning instructions (see 9. Commissioning, below).
Commissioning and Troubleshooting Guide VersiCharge™ SG 6.7 Diagnostics file download feature Customer service may request a diagnostic zip file be emailed to them. This will be used for further troubleshooting. NOTE: The charge must either stay in AP mode or in Client mode in order to do this download. Diagnostics file download Navigate to the cloud, https://versichargesg.cloudapp.net...
Page 26
VersiCharge™ SG Commissioning and Troubleshooting Guide Sample VS Access Point Name Access its local webpage with http://commission.versichargesg.net At the bottom of the Charger Commission page, select Download. There will be no immediate feedback that the button has been pressed. Allow 30-120 seconds. A download file, diag.zip, is being created during this time. When this is complete, diag.zip will download.
Page 27
Commissioning and Troubleshooting Guide VersiCharge™ SG Email the diagn.zip file to customer service. The Wi-Fi Status indicator is in any other state, Turn the VersiCharge circuit breaker to OFF> THEN Open cover and note state of Wi-Fi LED at tip of Wi-Fi module. You will not be able to access the local webpage. Replace the VersiCharge cover Turn the circuit breaker back ON.
Troubleshooting The Wi-Fi LED on the VersiCharge will indicate that it is connected to the local Wi-Fi network, but does not have connection to the VersiCharge SG Cloud. The Wi-Fi LED will alternate between colors following the sequences described below.
Page 29
Navigate to the local web page login page (http://commission.versichargesg.net). Provide the charger with the credentials set up for the cloud login to start the second connection attempt to the VersiCharge SG Cloud via the following: Enter the cloud account user credentials (used to set up account registration) to access the local web page. This navigates to the home page of the local web app.
Page 30
VersiCharge™ SG Commissioning and Troubleshooting Guide...
Commissioning and Troubleshooting Guide VersiCharge™ SG SECTION 8 Best Practices • Always stop the car from charging and unplug the car before a charger power cycle. • Power cycle Wi-Fi modem/router before troubleshooting begins (unplug and plug back in). • Have the homeowner connect a Wi-Fi enabled device to the Wi-Fi network that they are planning to use for the charger and test.
NOTE: Accessing local web pages allows you to operate your charger in Siemens cloud network, however, you cannot opt-in to utility demand response events. Additionally, by operating off the network, you cannot access the VersiCharge by using either the...
Page 33
Select your network connection Click Advanced You’ll find IP address information on the TCP/IP tab and the MAC address on the Hardware tab. Using Siemens Still can’t find the IP address: contact Siemens. The IP address will be provided within12-24 hours via email.
VersiCharge™ SG Commissioning and Troubleshooting Guide SECTION 10 Preparation For Commissioning 10.1 Prior to commissioning – confirm communication status Confirm communication status Unplug the car from the charger before troubleshooting. Power cycle the charger by turning the circuit breaker OFF then back ON. Test the network.
Page 35
Commissioning and Troubleshooting Guide VersiCharge™ SG Device does not return a ping. It is either (1) not powered up or (2) not communicating with the Wi-Fi network. THEN Review the power and communication status of each device. Device communication confirmed. No further action.
11.1 Smartphone, tablet , and cloud app setup The ability to control and monitor the VersiCharge SG remotely is what sets Siemens VersiCharge SG apart from previous products and our competitors. There are three different modes of communicating with the VersiCharge SG: •...
• Step 1: Select the grey check mark to indicate you have read the terms and conditions of use. The check mark will turn blue when selected. Full terms and conditions may also be found at: www.usa.siemens.com/VersiChargeSGApp . • Step 2: Enter your name and address, this information is used to suggest utilities and rate plans based on your location.
Page 38
Stop charging and unplug the car from the charger before troubleshooting. Ensure the breaker powering the dedicated branch circuit is in the OFF position, Plug in your VersiCharge SG. Turn breaker to ON position. The Power Available LED indicator will turn green, and the Wi-Fi Status LED Indicator will go through the following process: •...
Page 39
Navigate to the cloud and confirm that the charger now appears in the account. Verify that the VersiCharge SG account information, IP address and MAC address are the same in the local web pages as in the cloud. NOTE: unless already commissioned, the IP address and MAC address will not appear in the cloud account.
VersiCharge™ SG Commissioning and Troubleshooting Guide SECTION 12 Halo Operation 12.1 Halo states Halo indicator on VersiCharge indicates the status of the charging session. State mame Description Halo status indicator Power Available 240V or 208V Power Present Ready to Charge EV detected, waiting for charging command from EV Green - Solid Charging...
Wi-Fi module. However, it may be necessary to decommission the VersiCharge during troubleshooting. This may be necessary in order to allow the charger to connect to the VersiCharge Cloud from a different Wi-Fi network. Disconnect/decommission the charger from the VersiCharge SG Cloud Portal: •...
VersiCharge™ SG Commissioning and Troubleshooting Guide SECTION 14 Passwords Passwords are set at the time of cloud registration. The cloud account communicates with the VersiCharge through that password and credentials. If there is a password reset to the cloud account, allow 24 hours for the cloud to communicate with the VersiCharge.
• Navigate to the bottom of the Home page to find the Amps, etc.: • Amps - Current Amps at which the VersiCharge SG is charging. • Adjusted Amps - The position of the amperage adjustment dial inside the charger.
Page 44
This document contains a general description of available technical options only and its effectiveness will be subject to specific variables, Siemens Industry, Inc. including field conditions and project parameters. Siemens does not 3617 Parkway Ln. make representations, warranties, or assurances as to the accuracy or Peachtree Corners, GA 30092 completeness of the content contained herein.