...4 CONFIGURATION

4.6.6 Scales

Note. The scales configured here are used to scale analog channel data in the Chart View when 'Configuration type' is set
to 'Advanced' – see Section 4.4.1. It has no effect on the Bargraph View (which always uses the engineering range of the
analog signal displayed – see Section 4.6.2) or on digital channels.
88
Set within the range –999 to 9999.
A
Set within the range –999 to 9999.
A
Set within the range –999 to 9999.
A
Typically set to a lower value than 'Primary range low'. When
selected in the Chart view (see Section 2.3), enables the
Operator to zoom in on data displayed.
Set within the range –999 to 9999.
A
Typically set to a lower value than 'Primary range high'. When
selected in the Chart view (see Section 2.3), enables the
Operator to zoom in on data displayed.
Select a signal source to enable switching between the
A
channel's primary and secondary scales. Refer to
APPENDIX 1 for a description of the available sources.
Note. This signal is edge-triggered. A rising edge (inactive to
active) switches to the secondary scale. A falling edge (active
to inactive) switches to the primary scale.
Secondary
Primary