...4 CONFIGURATION
...4.4.5 Users
Note. The following parameters are displayed only if 'Security system' is set to 'Advanced' – see Section 4.4.4.
58
Configure User 1 (System Administrator)
Note. Full Configuration level access privileges for User 1
cannot be disabled but Setup level access and the Electronic
Signature privilege may be enabled/disabled as required.
The System Administrator (User 1) can view and/or change
the user name, access privileges and password for any other
user. Select the user to be viewed/edited.
Enter a name for the selected user.
Set access privileges for the selected user.
Disabled
– The selected user is unable to access
the Configuration and Setup levels or
enter electronic signatures.
Setup
– The selected user is able to access the
Setup level.
e-Sign
– The selected user is able to enter an
electronic signature.
Config (Full)
– The selected user is allowed full
configuration access with the exception
of access to the Audit Log size setting
and the Security Settings.
Note. The System Administrator (User 1) only is able to
change the Audit Log size and the Security Settings.
Config (Ltd)
– The selected user is able to:
• Change alarm trip points, hysteresis
and time hysteresis settings.
• Make input adjustments for analog
input boards.
• Load configurations from external
media only.
Config (Load) – The selected user is unable to make any
configuration changes but can load
configurations from external media.
Enter an initial password for the selected user.
Note. The user may change this password.