CMTS 1000 Installation Manual V1.2
Downstream Frequency
The receive frequency entered in this field (in MHz) is the one used by all
CMs in this network.
Upstream Channel ID
The Upstream Channel ID, which the CM must use, is an override for the
channel selected during initialization.
Maximum CPEs
The entry in this field allows you to control the maximum number of Cus-
tomer Premise Equipment (CPE) that this CM will support. The CM sup-
ports from a single client node up to sixteen client nodes.
Time Zone
The entry in this field is the timezone. It is updated from the timezones
table of the database. It is used in the time stamps in the CM event log.
Daylight Savings Time
Check this box when daylight savings time is in effect. It is used in the time
stamps used in the CM event log.
LLC Filters
This option allows you to add a Logical Link Control (LLC) filter to all
CMs on this network. An LLC filter must be created using the LCn Control
Panel MIB Objects Tab Filters option before you can add a filter type to a
network.