Power
Variable Name:
Set/Get Response/Status:
Description:
IfUpstreamChannelEntry
The following paragraphs include the SNMP Syntax (Set/Get Response
and/or Status) and a general description of the status entry for each MIB
variable in the docsIfUpstreamChannelEntry table.
The following table is implemented on both the Cable Modem and the
Cable Modem Termination System.
This table provides a list of attributes for a single upstream channel. An
entry in this table exists for each ifEntry with an ifType of docsCableUp-
stream(129).
ifIndex
Variable Name:
Set/Get Response/Status:
Description:
302693-B Rev 00
docsIfDownChannelPower
Number (TenthdBmV)
At the CMTS, the operational transmit power.
At the CM, the received power level. May be
set to zero at the CM if power level measure-
ment is not supported. If the interface is
down, this object either returns the config-
ured value (CMTS), the most current value
(CM) or the value of 0.
ifIndex
Number
A unique value for each interface. Its value
ranges between 1 and the value of ifNumber.
The value of each interface must remain con-
stant at least from one reinitialization of the
entity's network management system to the
next reinitialization.