Forwarding_Count; Forwarding_Timer - Nortel 2000 Software Reference Manual

Nortel remote annex 2000 server: reference guide
Hide thumbs Also See for 2000:
Table of Contents

Advertisement

Chapter 2
Configuration Parameters
Remote Annex Administrator's Guide for UNIX
Book C-60

forwarding_count

This asynchronous port parameter controls Annex port behavior for
received characters. When set to a number other than zero, the port does
not forward characters until it receives the specified number of characters.
When set to zero, the port uses the value in the forwarding_timer
parameter. Allowable values range from 0 to 255. The default is 0.
If you use both forwarding_count and forwarding_timer, the
Annex uses the value that occurs first.
Setting forwarding_count to one or forwarding_timer to zero may
have a severe effect on the network when heavy serial input occurs.

forwarding_timer

This asynchronous port parameter sets the amount of time in ten
millisecond (ms) intervals that can elapse before an Annex forwards
received data. If new data arrives before the timer expires, the Annex
resets the timer. Allowable values range from 0 to 255 or off. The default
is 5 (50 ms); if you set the value to 0, the Annex uses 5.
If you use both forwarding_count and forwarding_timer, the
Annex uses the value that occurs first.
Setting forwarding_count to one or forwarding_timer to zero may
have a severe effect on the network when heavy serial input occurs.
Book C

Advertisement

Table of Contents
loading

This manual is also suitable for:

4000539061005391

Table of Contents