Chapter 2
Configuration Parameters
Book C
tmux_max_host
This Annex parameter specifies the maximum number of host addresses
allowed in the TMux address table. If the number of host addresses
exceeds the value entered here, the Annex discards the oldest entry.
Allowable values are 10 through 255; the default is 64.
tmux_max_mpx
This Annex parameter specifies the largest user packet that can be placed
in a TMux packet. The Annex does not multiplex larger packets, but
passes them directly to the IP layer. Allowable values are 5 through 65535;
the default is 700.
tni_circuit_id
This T1 parameter stores the T1 circuit identifier string. The T1 circuit
identifier string comes from the service provider and is used for customer
service calls. The parameter setting is a string of up to 120 characters.
The default setting is the null string.
tni_clock
This T1 parameter sets the clock for the T1 Network Interface. Parameter
settings include loop (service provider), local (Annex), external (T1
Drop/Insert Interface). The default setting is loop.
Remote Annex Administrator's Guide for UNIX