Maintenance and service

8.1

Storage and transport

Observe the following general conditions when storing and transporting the Wallbox:
• The permissible storage temperature of the Wallbox is -25 °C to +80 °C.
• The permissible air humidity is 5 to 98%, no condensation.
• The Wallbox may only be transported in the transport packaging provided for this purpose
using the supplied safety and shock-absorbing materials.
• Disconnect all external cable connections for the transport of the Wallbox.
Set switches of the fuses to the "Off" position.
Close any transport locks on the cover.
• Avoid shocks and impacts during transport.
8.2

Cleaning and maintenance

Safety measures
NOTE
Before performing cleaning or service work, disconnect the system from the power and
ensure it cannot be switched back on. To do this, deactivate at least all fuses to which the
Wallbox is connected.
Risk of electrocution
Touching live parts may cause electric shock or death.
Turn off all power supply to the unit before cleaning charging cables. Secure the Wallbox
against being switched on again.
Risk of electrocution
Do not use steam jets or water jets for cleaning, as they may cause moisture to ingress the
Wallbox. Moisture inside the Wallbox poses a risk of electric shock.
The manufacturer is not liable for damage resulting from improper cleaning methods.
VersiCharge AC Wallbox Operating Instructions ERK
Operating Instructions, 08/2023, A5E51549696-AC
DANGER
DANGER
8
67