This mode requires a calibration factor to run
(see
Calibration Procedure, page
1. Enter Setup Mode and navigate to System
screen 3.
2. Select Resistance from the drop-down menu.
NOTE: If no calibration factor is shown,
NOTE:
NOTE:
follow the
Calibration Procedure, page
NOTICE
NOTICE
NOTICE
To prevent damage to the heated hose, a
hose calibration is required if any of the
following conditions are true:
• The hose has never been calibrated
before.
• A section of hose has been replaced.
• A section of hose has been added.
• A section of hose has been removed.
3. Enter Run Mode and navigate to the Targets
screen. Use the up and down arrows to set
the desired temperature.
333023U
Mode
Mode
56).
4. Navigate back to the Run Mode home screen.
56.
NOTE: Hose Resistance Mode controls the
NOTE:
NOTE:
average fluid temperature of the A and B
fluid. Set the hose temperature set point
halfway between the A and B temperature
set points and adjust as needed to achieve
desired performance.
The Hose Resistance Mode icon will display.
NOTE:
NOTE: When Hose Resistance Mode is
NOTE:
enabled and the hose heat is off, the hose
temperature will display "- - -". In Hose
Resistance Mode, temperature values are
only displayed when the heat is on.