Advanced Display Module (ADM) Operation
Home
Home
Home Screen
Screen
Screen - - - System
System With
System
Active errors are shown in the status bar. The
error code, alarm bell, and description of the
error will scroll in the status bar.
1. Press
to acknowledge the error.
2. See for corrective action.
Targets Screen
Screen
Targets
Targets
Screen
Use this screen to define the setpoints for
the A Component Temperature, B Component
Temperature, heated hose temperature, and
pressure.
Maximum
Maximum A A A and
Maximum
and B B B temperature:
and
temperature: 190°F (88°C)
temperature:
Maximum
Maximum heated
Maximum
heated hose
heated
hose temperature:
hose
above the highest A or B temperature setpoint
or 180°F (82°C).
NOTE: If the remote display module kit is used,
NOTE:
NOTE:
these setpoints can be modified at the gun.
40
With Error
With
Error
Error
temperature: 10°F (5°C)
temperature:
Maintenance Screen
Maintenance
Maintenance
Screen
Screen
Use this screen to view daily and lifetime cycles
or gallons that have been pumped and gallons
or liters remaining in the drums.
The lifetime value is the number of pump cycles
or gallons since the first time the ADM was
turned on.
The daily value automatically resets at midnight.
The manual value is the counter that can be
manually reset. Press
manual counter.
Cycles Screens
Screens
Cycles
Cycles
Screens
This screen shows daily cycles and gallons that
have been sprayed for the day.
All information listed on this screen can
be downloaded on a USB flash drive. See
Download Procedure, page
and hold to reset
69.