RDL-3000
5
CLI Interface
This section describes the procedures for configuring and operating the RDL-3000 using
CLI over a Telnet connection. The following procedures require a PC equipped with a
Web browser, Ethernet port, and an Ethernet Cat-5e crossover cable for connection to
the PoE power adapter. The IP address and subnet mask of the PC must be on the
same subnet as the RDL-3000.
For example:
5.1
Telnet Access
Use the following steps to establish a Telnet session with the RDL-3000. Refer to the
RDL-3000 User Manual section 5: CLI Interface for a complete description of the
available commands.
1. On the PC, open a Telnet client and enter the unit IP address. The factory default IP is
'192.168.25.2'.
2. Login to the RDL-3000 using the assigned username and password. The default username is
'admin', and the default password is 'admin'.
For example,
telnet 192.168.25.2
username: admin
password: admin
5.2
Command Summary
Online help is available for all commands, and the Tab key can be used for auto-
complete functions. The following table lists all RDL-3000 commands available from root
mode (default mode when you login).
Command
apply
arp
chgver
clear
del
enable
freq
generate
get
load
logout
new
ping
reboot
reset
save
User Manual
IP address =
192.168.25.11, Net Mask =
Table 11: CLI - Command Summary
Description
Activate changes without overwriting saved configuration.
Add a static ARP definition to the RDL-3000 ARP table.
Change default version of firmware and reboot.
Clear commands.
Delete an ID.
Enable an ID.
Enter frequency ranges for autoscan and DFS.
Create DSA key for SSH locally on RDL-3000.
Display the value of a statistic or parameter.
Load commands.
End the current Telnet session.
Create a new ID.
Send a ping message from the RDL-3000 system.
Reboot the RDL-3000.
Reset the RDL-3000 statistics values.
Save the selected configuration settings.
Chapter 5
255.255.255.0