Programming The Network Loop - Nortel Meridian Mail Installation Quick Reference Manual

Modular option ec
Hide thumbs Also See for Meridian Mail:
Table of Contents

Advertisement

9-20

Programming the network loop

To program the network loop operation
Overlay 17—Network loop
Prompts
Responses
REQ
CHG
TYPE
CFN
.
<cr>
CEQU
YES
.
<cr>
.
TERD
0–159
<cr>
Standard 1.0
Step Action
1
Load Overlay 22 and print out the Configuration Record.
2
Select a loop that is not already reserved.
3
Load Overlay 17 and configure each network loop as outlined
in the X11 Input/Output Guide (NTP 553–3001–400). Refer to
the section "Common Equipment, 'CEQU'".
Modular Option EC Installation Quick Reference Guide
Configuring the Meridian 1 for Meridian Mail
Description
Change
Configuration data block
Carriage return
Gate–opener for common equipment parameters
Carriage return
Enter the loop number you selected for Meridian
Mail, according to where you installed the loop
card.
Carriage return until all prompts are finished and
your entry is updated.
Repeat from the top of the table for each loop
Programming the network loop
November 1999