Nortel Meridian Mail Installation Quick Reference Manual page 176

Modular option ec
Hide thumbs Also See for Meridian Mail:
Table of Contents

Advertisement

10-2
Starting up Meridian Mail
To start up Meridian Mail
Note: If any problems occur during startup, see I&M, Chapter 16.
Standard 1.0
Step Action
1
Power on the administration terminal, printer, and other
peripheral devices.
2
On the administration terminal, press <Ctrl> and <Print
Screen> to turn on automatic printing.
3
Before you power up the Meridian Mail system, look at
" Behavior of LED indicators when starting up Meridian Mail
on page 10-3 and be prepared to verify the proper behavior
of the LEDs visible at the front of each module.
Be prepared to observe the hexadecimal display on the front
of the Enhanced MMP40 or MMP40 card (see " Hexadecimal
display on the Enhanced MMP40 or MMP40 card" on page
10-4).
4
Power up the Meridian Mail system by setting the main
breaker switch for each column to ON, and shelf breakers or
DCEPS switches to
If your system has more than one Meridian Mail module,
power on module MM0, followed by module MM1 and
module MM2.
In an AC system, switch on the upper breaker in each module
before the lower breaker.
In a DC system, switch on the left DCEPS in each module
before the right one.
As part of the bootup process, the administrator's terminal
displays a series of diagnostic and information messages.
The bootup messages that should appear are outlined in I&M,
Chapter 16.
5
Check for power problems:
LEDs on the power units at the base of the column indicate
that power is on. You should hear the fans in the base of the
column.
Modular Option EC Installation Quick Reference Guide
Starting up and configuring Meridian Mail
.
ON
Starting up Meridian Mail
November 1999