Nortel Meridian Mail Installation Quick Reference Manual page 56

Modular option ec
Hide thumbs Also See for Meridian Mail:
Table of Contents

Advertisement

5-12
Installing the disk drives
See the illustration that follows this procedure
Standard 1.0
Step Action
1
Turn off the shelf breakers (on an AC module) or module power
supply switches (on a DC module).
2
Ensure that the SCSI ID has been set properly on each disk
drive. See Chapter 4.
3
Install the primary disk drive in slot MSU2.
4
If the system is shadowed, install the secondary disk drive (the
drive with the power supply on the drive plate) in slot MSU3.
Modular Option EC Installation Quick Reference Guide
Installing a one-node system
Location of components in the module

Risk of electrocution
Before installing disk drives in an AC
module, ensure that shelf breakers are
OFF.
Before installing disk drives in a DC
module, ensure that the module power
supply switches are OFF.
 
Risk of equipment damage
Wear an antistatic wrist strap when
handling disk drives. As an additional
safety measure, handle drives by the edges
and, whenever possible, with the loosened
packing material still around the drive.
Disk drives are susceptible to damage
from rough or improper handling.
.
November 1999