648 Port InfiniBand FDR Switch Platform Hardware Installation Guide
Step 3.
Measure the distance between the vertical supports and adjust the shelf brack-
ets according to this distance. This chassis can be installed in a rack with a
distance between the vertical supports of from 65cm(25.6in.) to
80cm(31.5in.).
Step 4.
The shelf comes with the four brackets pre-installed. Two of the brackets
should be loose. They may need to be removed and repositioned to meet the
distance between the vertical supports of the rack.
Mellanox Technologies
Figure 5: Vertical Rack Supports Dimension
Figure 6: Adjustable Shelf Brackets
Vertical Supports
These two brackets will
need to be adjusted. They
may even need to be
removed and repositioned.
The holes in the bracket are off-
set to one side.
The holes must be closer to the
top of the shelf.
Rev 1.4
17