[:Input]:Scaling:{Vt|Ct|Sfactor}:Element<X; [:Input]:Synchronize - Teledyne T3PM1100 User Manual

Digital power meter
Hide thumbs Also See for T3PM1100:
Table of Contents

Advertisement

Find Quality Products Online at:
Return parameter 0
1
Example
:INPUT:SCALING:STATE ON
:INPUT:SCALING:STATE?
->:INPUT:SCALING:STATE 1
[:INPut]:SCALing:{VT|CT|SFACtor}:ELEMen
t<x>
Sets or returns the VT ratio, CT ratio, or power
Description
coefficient of the specified element.
Syntax
[:INPut]:SCALing:{VT|CT|SFACtor}:ELEMent<x>
{<NRf>}
Query Syntax
[:INPut]:SCALing:{VT|CT|SFACtor}:ELEMent<x>?
Parameter/
<x>
Return parameter
<NRf>
Example
:INPUT:SCALIG:VT:SRATIO:ELEMENT1 10
:INPUT:SCALIG:VT:SRATIO:ELEMENT1?
->:INPUT:SCALIG:VT:SRATIO:ELEMENT1 10

[:INPut]:SYNChronize

Sets or returns the synchronization source.
Description
Syntax
[:INPut]:SYNChronize {VOLTage|CURRent|OFF}
Query Syntax
[:INPut]:SYNChronize?
Parameter/
VOLTage
Return parameter
154
GlobalTestSupply
www.
T3PM1100 User Manual
Turn the scaling function off.
Turn the scaling function on.
Set
Query
1(If <Element> is omitted, the element
is
set to 1)( For the T3PM1100, only set to
1
or omitted)
0.001 to 9999
Set
Query
Select the voltage synchronization
source.
.com