Find Quality Products Online at:
[:INPut]:VOLTage:AUTO
Sets or returns the voltage auto range on/off state.
Description
Syntax
[:INPut]:VOLTage:AUTO {<Boolean>|OFF|ON}
Query Syntax
[:INPut]:VOLTage:AUTO?
Parameter
<Boolean>0 OFF
<Boolean>1 ON
Return parameter 0
1
Example
:INPUT:VOLTAGE:AUTO ON
:INPUT:VOLTAGE:AUTO?
->:INPUT:VOLTAGE:AUTO 1
[:INPut]:VOLTage:CONFig
Sets or returns the valid voltage range.
Description
Syntax
[:INPut]:VOLTage:CONFig {ALL|<Voltage>[,Voltage]...}
Query Syntax
[:INPut]:VOLTage:CONFig?
Parameter/
ALL
Return parameter
<Voltage>
Example
:INPUT:VOLTAGE:CONFIG 300,150,30
:INPUT:VOLTAGE:CONFIG?
->:INPUT:VOLTAGE:CONFIG 300.0E+00,150.0E+00,
30.0E+00
[:INPut]:VOLTage:POJump
Sets or returns the jump destination range that is
Description
used when a voltage peak over-range occurs.
Syntax
[:INPut]:VOLTage:POJump {OFF|<Voltage>}
148
GlobalTestSupply
www.
T3PM1100 User Manual
Set
Query
Turn the voltage auto range function off.
Turn the voltage auto range function on.
Set
Query
All ranges are valid.
See(:INPut:VOLTage:RANGe).
Set
Query
.com
sales@GlobalTestSupply.com