7.

Decommissioning

7.1

Change of location

Heed the following if the EPS 205 is to be relocated:
R
Unplug the electrical connection.
R
Disconnect the pneumatic connection.
R
Drain the test oil out of the test oil tank (see sec.
6.2.6 , steps 1 to 8).
R
Re-fit the transportation safeguards for the drive
unit (see sec. 4.4. ).
R
The EPS 205 is only to be transported in a crate.
If the EPS 205 is to be sold or passed on, all the
documentation included in the scope of delivery must
be handed over together with the unit.
7.2

Disposal and scrapping

Before scrapping, the test oil in the EPS 205 must be
drained off. The pipe filter at the flowmeter, the intake
filter in the test oil tank and the filter mats for external
extraction in the jet chamber unit must also be removed
and disposed of.
i
Test oil as per ISO 4113 is classified under used oil
iicollection category 1. In category 1, the used oil
must not contain any foreign substances such as
used oils of a different category, gasoline or diesel
fuel. The corresponding refuse code number can be
taken from the safety data sheet of the test oil.
EPS 205, accessories and packaging should
be sorted for environmental-friendly recycling.
Do not dispose EPS 205 into household
waste.
Only for EC countries:
The EPS 205 is subject to the European
directive 2012/19/EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
Make use of the local return and collection
systems for disposal.
Proper disposal of EPS 205 prevents
environmental pollution and possible health
hazards.
Robert Bosch GmbH
Decommissioning | EPS 205 | 69
8.

Technical data

8.1
EPS 205
Function
Rated three-phase AC voltage
Rated current
Fuse
Number of phases
Input frequency
Rated power
Compressed air
Storage temperature
Operating temperature
Ambient temperature
for measurement accuracy
Max. perm. relative humidity
Degree of protection
Oil pressure
Maximum speed
Control voltage
Atmospheric pressure
corresponding to an altitude of
Longer conditioning times must be expected at ambient
*)
temperatures above 25 °C.
Function
Tightening torques for high-pressure
connection, screw plug and hoses
Test oil tank capacity
8.2

Noise emissions

Function
Emission sound pressure level
at workplace as per DIN EN ISO 11201
Sound power level as per DIN EN ISO 3744
8.3

Dimensions and weights

Function
EPS 205 (H x W x D)
Weight of EPS 205 incl. packaging
Weight of EPS 205
(without test oil and packaging)
Oil collector (H x W x D)
en
Specification
380 VAC – 460 VAC
15 A
16 A
3P - PE
50 Hz / 60 Hz
4,2 KW
0.5 MPa − 0.8 MPa
-25 °C – 60 °C
5 °C – 40 °C
*)
10 °C – 35 °C
≤90 % (25 °C,
24 hours duration)
IP 22
180 MPa
3500 min
-1
24 VDC
700 hPa – 1060 hPa
≤2200 m
Specification
25 Nm − 30 Nm
6.5 l
Specification
< 71.5 dB(A)
< 84.1 dB(A)
Specification
580 x 560 x 780 mm
210 kg
138 kg
30 x 570 x 720 mm
|