8.

Maintenance

8.1

Spare and wearing parts

Description
Filter drier
Filter hose
8.2

Replacing the filter drier

1. Make sure the RG8.0 / RG4.0 is switched off and
disconnected from mains supply before proceeding.
2. Ensure that residual refrigerant in the RG8.0 / RG4.0
is purged. Refer to section 6.2
3. Ensure that the inlet and outlet valve pressure is zero.
4. Remove the inlet hose if still connected to the
A/C or refrigeration system.
5. Uninstall the filter drier.
6. Replace with a new filter drier
(order number 100343
8.3

Resetting the high pressure switch

1. Make sure the RG8.0 / RG4.0 is switched off.
2. Check if the recovery tank is overfilled.
3. Close the recovery tank valve(s), the hose shut-off
valve(s) connected to the tank, and the inlet and
outlet control valves of the RG8.0 / RG4.0.
4. Disconnect the hose(s) only from the recovery tank.
Retain the hose connections to the RG8.0 / RG4.0.
5. Connect the hose(s) to another recovery tank which
is empty.
6. Open the recovery tank valve(s).
7. Open the outlet control valve of the RG8.0 / RG4.0.
8. Open the shut-off valve in the hose connected to
the recovery tank liquid port and allow refriger-
ant to flow and pressure on the outlet side of the
RG8.0 / RG4.0 to drop.
9. Once the pressure in the outlet of RG8.0 / RG4.0
drops below 28 bar, switch on the RG8.0 / RG4.0.
10. When the RG8.0 / RG4.0 restarts, slowly open the
inlet control valve of the RG8.0 / RG4.0 and resume
recovery. If in push / pull configuration, it will also
be necessary to open the shut-off valve on the hose
connected to the vapour port of the tank.
i
Once the safety pressure switch is activated, it
will remain open until the pressure within the
RG8.0 / RG4.0 is reduced below 28 bar, at which
time it will automatically reset. It is not possible to
operate the RG8.0 / RG4.0 until this occurs.
Bosch Automotive Service Solutions GmbH
Order number
100343
100345
).
Maintenance | RG8.0 / RG4.0 | 37
9.

Decommissioning

9.1

Disposal of electronic items

This product is subject to European guidelines
2002/96/EG (WEEE).
R
Old electrical and electronic devices, including ca-
bles and accessories or batteries must be disposed
of separate from household waste.
R
Use the return and collection systems in place for
disposal in your area.
R
Damage to the environment and hazards to personal
health can be prevented by properly disposing of old
equipment.
R
Follow local regulations for disposal of electronic items.
9.2

Disposal of refrigerants and oils

Refrigerants that can no longer be used must be
handed over to the gas suppliers for disposal. The oils
recovered from the A/C or refrigeration system must be
disposed in accordance with local regulations.
Refrigerants which are unknown must be disposed in
accordance with local regulations. Contact local refrig-
erant suppliers or competent authorities for informa-
tion regarding handling and disposal of refrigerants and
lubricants.
9.3

Disposal of filter drier

Dispose the filter drier through the designated return
points or in accordance with local regulations.