Intel® Server System M50FCP1UR System Integration and Service Guide
8. Carefully lift and turn over the heat sink.
9. Align the Pin 1 indicator of the processor carrier clip with the corner cut-out on the heat sink (See
Figure 85.
Note: For the standard heat sink, there are two cut-out corners; either can be used to align Pin 1
indicators.
10. Gently press down the heat sink onto the processor carrier clip until it clicks into place.
11. Ensure that all four heat sink corners are securely latched to the carrier clip tabs.
6.5.3

Processor Installation

Caution: Do not touch the socket pins. The pins inside the processor socket are extremely sensitive. A
damaged processor socket may produce unpredictable system errors.
1. (If present) Remove the protective cover by squeezing the finger grips (see Letter A) and pulling the
cover up and away from the processor socket. See Letter B.
Caution: Ensure that the processor socket is free of damage or contamination before installing the PHM. If
debris is observed, blow it away gently with an air blower. Do not use tweezers or any other hard tools to
remove it manually.