M.2 Storage Device Installation; Figure 47. Ocp* Adapter With Internal Lock Installation; Figure 48. M.2 Ssd Connector Location - Intel M50FCP1UR Manual

Server system
Table of Contents

Advertisement

Intel® Server System M50FCP1UR System Integration and Service Guide
1. Power off the system and disconnect the system power cords.
2. Remove the system top cover (see
3. If present, remove the riser card assembly above the OCP adapter area, (see
Note: In the default shipping configuration, the internal lock is set to the unlock orientation.
4. Squeeze the two hooks of the internal lock and pull it out (see Letter A).
5. Align the OCP* adapter with the open OCP bay slot and slide forward until the connectors make
secure contact (see Letter B).
6. Reinstall the internal lock with the lock orientation (see Letter C).
7. Reinstall the riser card assembly as needed (see
8. Reinstall the system top cover (see
3.6

M.2 Storage Device Installation

The server board includes two M.2 connectors as shown in the following figure. Each M.2 connector supports
a PCIe* NVMe* or SATA SSD drive that conforms to a 22110 (110 mm) or 2280 (80 mm) form factor.
Required Tools and Supplies
M.2 SSD
Anti-static wrist strap and conductive workbench pad (recommended)
Phillips* head screwdriver #1
44

Figure 47. OCP* Adapter with Internal Lock Installation

Section
Section

Figure 48. M.2 SSD Connector Location

3.1.1)
Section
3.2.4).
3.1.2).
Section
3.2.1).