Intel® Server System M50FCP1UR System Integration and Service Guide
2. Set anti-tilt wires on all four corners of the heat sink to the inward position (see Letter A in
3. Align the Pin 1 indicators of the processor carrier clip and processor with the Pin 1 indicator on the
bolster plate located around the processor socket (See
Caution: Processor socket pins are delicate and bend easily. Use extreme care when placing the PHM
onto the processor socket. Do not drop it.
4. Carefully lower the PHM onto the bolster plate alignment pins (see Letter B).
5. Using a Phillips #2 screwdriver, tighten the heat sink extension screws (see Letter C).
6. Set all four anti-tilt wires on the heat sink to the outward position (see Letter D).
Figure 87. PHM Alignment with Socket Assembly
Figure 88. PHM Installation onto Server Board
Figure
87.
Figure
88).
69