9. Align and insert the M.2 SSD with the connector on the server board. See Letter A.
10.
11. Using the screw, secure the SSD to the mounting stand-off on the server board
(see Letter B). Tighten to 1.5 in-lb.
12. Reinstall the riser card assembly (see
13. Reinstall the system top cover (see
6.11 Intel® RAID Maintenance Free Backup Unit (RMFBU) Replacement
This section provides instructions to replace an RMFBU bracket and assembly in the system.
Required Tools and Supplies
Replacement RMFBU Kit
Anti-static wrist strap and conductive workbench pad (recommended)
1. Remove the system top cover (see
2. Disconnect RMFBU cables.
3. Locate the RMFBU housing assembly and slide the latch up to unlock the assembly from the
mounting plate (see Letter A).
4. Slide the RMFBU housing assembly (see Letter B) towards the system fans. When free from the
mounting plate, lift it up and out of the system.
5. Remove the RMFBU from the plastic housing
6. Locate and carefully unpack the replacement RMFBU
Section
Figure 115. Intel® RMFBU Mounting Bracket Removal - Chassis
Section

Figure 116. RMFBU Housing Assembly

Section
6.6).
6.1.2).
6.1.1).
83