Intel® Server System M50FCP1UR System Integration and Service Guide
Note: Intel recommends holding the drive with one hand while holding the lever with the other hand.
4. Slide the drive forward until it is fully connected with the backplane (see Letter B).
5. Complete the drive installation by closing the drive extraction lever until it locks into place
(see Letter C).
6.8

2.5" Drive Mounting Rail Replacement

Removal of the drive rail from the drive bay is not required when servicing an SSD. However, if damaged, the
drive rail can be removed from the chassis for repair and or replacement.
Required Tools and Supplies
2.5" drive mounting rail kit
Anti-static wrist strap and conductive workbench pad (recommended)
The following figure shows the backside of the drive mounting rail identifying the two mounting rail studs
and the tab.
1. Remove the drive mounting rail from the front drive bay.
Release and set the extraction lever to the fully open position
Looking inside the drive bay, visually locate the locking tab on the drive rail
78

Figure 105. Drive Mounting Rail Features Identification

Figure 106. Removing Drive Mounting Rail