SECTION 6

6-1 PREPARATION

■ REQUIRED EQUIPMENT
EQUIPMENT
Adjustment software ID-RP3 ADJ
Output voltage:
DC power supply
Current capacity: 10 A or more
Measuring range: 0.1 ~ 30 W
RF power meter
Frequency range: 100 ~ 300 MHz
(50 Ω terminated)
SWR:
Frequency range: 300 ~ 3000 Hz
Audio generator (AG)
Output level:
■ SAVE THE PROGRAMMING DATA
• Adjusting the repeater will change the programming setting.
• Before adjusting, save the programming data of the repeater with the programming software.
After adjusting, write back the programming data.
■ CONNECTIONS
RF POWER METER
Always connect the power
meter during adjustment.
10 MHz
REFERENCE FREQUENCY
SIGNAL SOURCE
STANDARD SIGNAL
GENERATOR
Supplied USB cable
PC

ADJUSTMENT PROCEDURE

GRADE AND RANGE
13.8 V
1.2 : 1 or less
1 ~ 500 mV
<Rear view>
EQUIPMENT
Programming cable USB cable ( Supplied with the repeater)
Frequency range: 0.1 ~ 300 MHz
Standard signal
Output level:
generator (SSG)
10 MHz reference
Frequency:
frequency signal
Accuracy:
Output level:
source
AC millivoltmeter
Measuring range: 1 mV ~ 10 V
To [DC13.8V]
Supplied DC power cable
AUDIO GENERATOR
4.7 µF
+
[MIC]
[GND]
(3.5 mm, ⅛ in (d))
PLUG INFORMATION
Parts name:
Order number: 5610000420
6-1
GRADE AND RANGE
−20 to 90 dBμV
(−127 to −17 dBm)
10.000000 MHz
-4
±5×10
ppm or less
97 dBμV (−10 dBm)
DC POWER SUPPLY
_
25 A fuses
AC MILLIVOLTMETER
+ −
+ −
AP-338
+

Advertisement