Note: AGC output configuration with the zeroing function:
By activating the zeroing function on the main page, the noise levels at the inputs of the Pre D
combiner have been balanced, but this has not changed the AGC outputs.
The following Pop-up shows the display of the AGC outputs using the absolute mode.
To set the « 0 » of the AGC to the noise level measured, the AGC is switched to the "Strength mode".
On the following Pop-up:
The AGC low level (0 V) corresponds to the Noise level measured.
The AGC high level (5 V) corresponds to the max level (- 10 dBm).
Nota 1:
The level in the Min case should be the noise level measured and it should be grey so that
the user
could not change it.
Nota 2:
By activating, the AGC mode strength, the user changes the slope of the AGC.
© Safran Data Systems – IMP000074 e14r1
Radio Telemetry Receiver
Graphical User Interface Manual
This document is the property of
It cannot be duplicated or distributed without expressed written consent.