Initialization Sequence - Safran RTR-NeXt User Interface Manual

Radio telemetry receiver
Table of Contents

Advertisement

3.1

Initialization sequence

1
After boot sequence, the machine connects automatically to the Cortex account.
2
The SPS is automatically started :
It loads every DLL and FPGA
It loads the default .CTX file
3
The MCS can then be started. It is automatic for the RTR and manual for the RX1 (from the
Menu)
4
When started, the MCS will automatically try to connect to the IP address stored in the MCS file
(localhost for a local address or any IP address for a distant connection)
5
The MCS permanently monitor the SPS (every 200ms approximately)
6
After each transfer, a comparison is done between MCS data and SPS data
If MCS data are the same as SPS data : OK is displayed
If there are difference between MCS and SPS : Differ is displayed
And different parameters are displayed with a yellow background
7.1 Possibility N°1 : Update MCS with SPS parameters
© Safran Data Systems – IMP000074 e14r1
Radio Telemetry Receiver
Graphical User Interface Manual
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
Ref.
D130486
Is.Rev
03
Customer Ref.:
-
Date:
21/06/2021
Safran Data Systems
.
Page 11