IBM x3690 X5 Service Manual page 260

Hide thumbs Also See for x3690 X5:
Table of Contents

Advertisement

Table 11. IMM error messages detected when MAX5 is attached to the server (continued)
Event ID
80080004-1d08xxxx
80080004-1d09xxxx
80080004-1d0axxxx
816f0008-1881xxxx
806f0308-1881xxxx
242
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Message
Device MEU Fan 3 has been
removed from unit
[PhysicalPackageElementName]
Device MEU Fan 4 has been
removed from unit
[PhysicalPackageElementName]
Device MEU Fan 5 has been
removed from unit
[PhysicalPackageElementName]
MEU PS 2 Status has
returned to OK status
MEU PS 2 Status has been
removed from container
"MEU PS 2 Status
MEU PS 2 Status has lost
input
Severity Description
Warning MEU Fan 3 is no
longer detected or is
not installed.
Warning MEU Fan 4 is no
longer detected or is
not installed.
Warning MEU Fan 5 is no
longer detected or is
not installed.
Info
MAX5 memory
expansion module
power supply 2 is
now normal.
Info
MAX5 memory
expansion module
power supply 2 is
now normal.
Info
MAX5 memory
expansion module
power supply 2 is
now normal.
Action
1. Install the fan, if
missing.
2. Reseat the fan
with the lit error
LED.
3. Replace the fan if
the problem
remains.
4. (Trained service
technician only)
Replace system
board.
1. Install the fan, if
missing.
2. Reseat the fan
with the lit error
LED.
3. Replace the fan if
the problem
remains.
4. (Trained service
technician only)
Replace system
board.
1. Install the fan, if
missing.
2. Reseat the fan
with the lit error
LED.
3. Replace the fan if
the problem
remains.
4. (Trained service
technician only)
Replace system
board.
No action;
information only.
No action;
information only.
No action;
information only.

Advertisement

Table of Contents
loading