Table 10. System x3690 X5 IMM error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192," on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service
technician.
Event ID
Message
806f010d-0400xxxx
The Drive n Status has been disabled
806f010d-0401xxxx
due to a detected fault.(n = hard disk
806f010d-0402xxxx
drive number)
806f010d-0403xxxx
806f010d-0404xxxx
806f010d-0405xxxx
806f010d-0406xxxx
806f010d-0407xxxx
806f010d-0408xxxx
806f010d-0409xxxx
806f010d-040axxxx
806f010d-040bxxxx
806f010d-040cxxxx
806f010d-040dxxxx
806f010d-040exxxx
806f010d-040fxxxx
806f010d-0410xxxx
806f010d-0411xxxx
806f010d-0412xxxx
806f010d-0413xxxx
806f010d-0414xxxx
806f010d-0415xxxx
806f010d-0416xxxx
806f010d-0417xxxx
806f010d-0418xxxx
806f010d-0419xxxx
806f010d-041axxxx
806f010d-041bxxxx
806f010d-041cxxxx
806f010d-041dxxxx
806f010d-041exxxx
806f010d-041fxxxx
806f0107-0301xxxx
An Over-Temperature Condition has
806f0107-0302xxxx
been detected on the Processor CPU n
Status.(n = microprocessor number)
806f011b-0701xxxx
The connector System board has
encountered a configuration error.
190
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Severity
Description
Error
A drive has been
disabled because of
a fault.
Error
An overtemperature
condition has
occurred for
microprocessor n.(n
= microprocessor
number)
Error
An interconnect
configuration error
has occurred.
Action
1. Run the hard disk drive
diagnostic test on drive
n.
2. Reseat the following
components:
a. Hard disk drive
(wait 1 minute or
more before
reinstalling the
drive).
b. Cable from the
system board to the
backplane
3. Replace the following
components one at a
time, in the order
shown, restarting the
server each time:
a. Hard disk drive
b. Cable from the
system board to the
backplane
c. Hard disk drive
backplane
(n = hard disk drive
number)
1. Make sure that the fans
are operating, that there
are no obstructions to
the airflow (front and
rear of the server), that
the air baffles are in
place and correctly
installed, and that the
server cover is installed
and completely closed.
2. Make sure that the heat
sink for microprocessor
n is installed correctly.
3. (Trained service
technician only) Replace
microprocessor n.
(n = microprocessor
number)
Reseat the front video cable
on the system board.