Sensor error #1.
00F0
Code (H)
Accessor encoder sensor B error detected
during blink check. Suspect the accessor
encoder sensor B.
00F1
Sensor error #2.
Accessor encoder sensor A error detected
during blink check. Suspect the accessor
encoder sensor A.
00F2
Sensor error #3.
X encoder sensor error detected during blink
check. Suspect the X encoder sensor.
00F3
Sensor error #4.
Magazine sensor error detected during blink
check. Suspect the magazine sensor.
00F8
Sensor error #5.
X origin sensor error detected during blink
check. Suspect the X origin sensor.
00F9
Sensor error #6.
Cartridge sensor error detected during blink
check. Suspect the cartridge sensor.
00FA
Sensor error #7.
Accessor forward sensor error detected
during blink check. Suspect the accessor
forward sensor.
00FB
Sensor error #8.
Accessor origin sensor error detected during
blink check. Suspect the accessor origin
sensor.

Drive error codes

Table 1
describes the drive error codes.
Code (H)
0200
Invalid data sent to drive.
NAK detected.
0201
Timeout error occurred while drive is waiting for
response.
0203
Drive disconnected.
0205
Drive busy.
0206
Command could not be executed because drive is
not mounted.
020E
Drive error detected.
020F
Unsupported drive detected.
0222
Media could not be ejected because drive is in
Prevent Medium Removal state.

Web User Interface error messages

Table 1
lists the Web User Interface error messages.
Title
Error
Users full.
You cannot remove yourself.
Parameter Error
Login failure.
Unsupported update file.
Invalid parameter found in [***].
Please input parameter of [***].
Password parameter error.
User name parameter error.
Not enough role.
A user name unmatched.
CHK 00F0
Panel
Description
Indication
CHK 00F1
CHK 00F2
CHK 00F3
CHK 00F8
CHK 00F9
CHK 00FA
CHK 00FB
Table 1. Drive error codes
Description
CHK 0200
CHK 0201
CHK 0203
CHK 0205
CHK 0206
CHK 020E
CHK 020F
CHK 0222
Table 1. Web user error messages
Message
Cycle the power supply and try again.
If the problem is corrected, run Library Verify before normal library operations
resume. See
Running library verify
If the problem persists, see
Panel
indication
1. Reseat all cables. See
2. Cycle the power supply and try again.
If the problem is corrected, run Library Verify before normal
library operations resume. See
If the problem persists, see
1. Release the drive Prevent Medium Removal state from the host.
2. Reseat all cables. See
3. Cycle the power supply and try again.
If the problem is corrected, run Library Verify before normal
library operations resume. See
If the problem persists, see
User Access
User Access
Login
Firmware Update
Configure Library
Configure Library
User Access
User Access
User Access
User Access
Action Required
test.
Contacting IBM technical
support.
Action Required
Reseating
cables.
Running library verify
Contacting IBM technical
Reseating
cables.
Running library verify
Contacting IBM technical
Issuing Panel
TS2900 Tape Autoloader 61
test.
support.
test.
support.