IBM x3690 X5 Service Manual page 142

Hide thumbs Also See for x3690 X5:
Table of Contents

Advertisement

Table 8. DSA messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192," on page 249 to determine
which components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
Trained service technician.
v Go to the IBM support Web site at http://www.ibm.com/supportportal/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Message
number
Component Test
201-801-xxx
Memory
201-802-xxx
Memory
124
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
State
Description
Memory
Aborted
Test canceled:
Test
the system UEFI
programmed the
memory
controller with
an invalid CBAR
address
Memory
Aborted
Test canceled:
Test
the end address
in the E820
function is less
than 16 MB.
Action
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the server firmware is at
the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this
component. For more information, see
"Updating the firmware" on page 397.
4. Run the test again.
5. If the failure remains, go to the IBM Web
site for more troubleshooting information
at http://www.ibm.com/systems/
support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that all DIMMs are enabled in
the Setup utility.
4. Make sure that the server firmware is at
the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this
component. For more information, see
"Updating the firmware" on page 397.
5. Run the test again.
6. If the failure remains, go to the IBM Web
site for more troubleshooting information
at http://www.ibm.com/systems/
support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.

Advertisement

Table of Contents
loading

Table of Contents