IBM x3690 X5 Service Manual page 251

Hide thumbs Also See for x3690 X5:
Table of Contents

Advertisement

Table 11. IMM error messages detected when MAX5 is attached to the server (continued)
Event ID
806f011b-1801xxxx
806f090c-258axxxx
806f090c-258bxxxx
806f090c-258cxxxx
806f090c-258dxxxx
Message
The connector
[PhysicalConnectorElementName]
has encountered a
configuration error
[PhysicalMemoryElementName]
on Subsystem
[MemoryElementName]
Throttled.
[PhysicalMemoryElementName]
on Subsystem
[MemoryElementName]
Throttled.
[PhysicalMemoryElementName]
on Subsystem
[MemoryElementName]
Throttled.
[PhysicalMemoryElementName]
on Subsystem
[MemoryElementName]
Throttled.
Severity Description
Error
MAX5 FPGA
configuration error.
Info
MEU Bank 1/2 :An
implementation has
detected memory has
been throttled.
Info
MEU Bank 3/4 :An
implementation has
detected memory has
been Throttled.
Info
MEU Bank 5/6 :An
implementation has
detected memory has
been throttled.
Info
MEU Bank 7/8 :An
implementation has
detected memory has
been throttled.
Action
1. AC power cycle
has occurred on
the server and
the MAX5.
2. Ensure that the
latest IMM, UEFI,
and FPGA
firmware is
installed on the
server (see
"Updating the
firmware" on
page 397).
3. Make sure that
the memory is
populated
correctly in the
server and the
MAX5.
Information only; no
action is required.
Information only; no
action is required.
Information only; no
action is required.
Information only; no
action is required.
233
Chapter 3. Diagnostics

Advertisement

Table of Contents
loading

Table of Contents