Removing The System Board - IBM x3690 X5 Service Manual

Hide thumbs Also See for x3690 X5:
Table of Contents

Advertisement

Removing the system board

Before you remove the system board from the server, take the following steps to
save data, firmware, and configuration data:
v Record all system configuration information, such as IMM IP addresses, vital
v Using the Advanced Settings Utility (ASU), save the system configuration to
v Save the system-event log to external media.
Note:
1. When you replace the system board, you must either update the server with
2. Before you attach a MAX5 to the server and try to use it, you must update the
To remove the system board, complete the following steps:
10. Remove the DIMMs from the system board and set them aside on a
11. Remove all PCI riser-card assemblies with the adapters in them (see
12. Remove the microprocessor air baffle (see "Removing the microprocessor air
360
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
product data, and the machine type, model number, serial number, Universally
Unique Identifier, and asset tag of the server.
external media.
the latest firmware or restore the pre-existing firmware that the customer
provides on a diskette or CD image. Make sure that you have the latest
firmware or a copy of the pre-existing firmware before you proceed.
server firmware with the latest level of firmware or code. If you attach and try
to use the MAX5 without updating the server firmware, you might get
unexpected system behavior or the server might not power on. For special
instructions to follow before you attach the MAX5 to the server, go to
http://www.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-
5085756.
1. Read the safety information and installation guidelines, see "Safety" on page
vii and "Installation guidelines" on page 261.
2. Turn off the server (see "Turning off the server" on page 17) and all attached
peripheral devices. Disconnect all power cords; then, disconnect all external
cables as necessary to replace the device.
3. If the server is in a rack, slide the server out of the rack.
4. Remove the server cover (see "Removing the server top cover" on page 264).
5. Disconnect all cables from the system board. Make a list of each cable as you
disconnect it; you can then use this as a checklist when you install the new
system board.
6. Disconnect all remote RAID battery cables from the adapters, if any are
installed.
7. Remove the fan cage assembly (see "Removing the fan cage assembly" on
page 331
8. Remove the DIMM air baffle, if one is installed (see "Removing the DIMM air
baffle" on page 270).
9. Remove the memory tray, if one is installed (see "Removing the memory tray"
on page 266).
static-protective surface for reinstallation (see "Removing a memory module"
on page 295).
Note: Make a note of the location of each DIMM as you remove it, so that
you can later reinstall it in the same connector.
"Removing a PCI riser-card assembly" on page 336).
baffle" on page 268).

Advertisement

Table of Contents
loading

Table of Contents