Table 11. IMM error messages detected when MAX5 is attached to the server (continued)
Event ID
806f0a0c-258axxxx
806f0a0c-258bxxxx
234
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Message
An Over-Temperature
Condition has been detected
on the
[PhysicalMemoryElementName]
on Subsystem
[MemoryElementName].
An Over-Temperature
Condition has been detected
on the
[PhysicalMemoryElementName]
on Subsystem
[MemoryElementName].
Severity Description
Error
MEU Bank 1/2
:Over-temperature
condition.
Error
MEU Bank 3/4
:Over-temperature
condition.
Action
1. Check Retain
TIPs for known
issues.
2. Check the IMM
event log for any
fan or cooling
related issues or
power related
issues.
3. Make sure that
the airflow at the
front and rear of
the chassis is not
obstructed and
that the fillers are
in place and
correctly
installed.
4. Make sure that
the room
temperature is
within operating
specifications.
1. Check Retain
TIPs for known
issues.
2. Check the IMM
event log for any
fan or cooling
related issues or
power related
issues.
3. Make sure that
the airflow at the
front and rear of
the chassis is not
obstructed and
that the fillers are
in place and
correctly
installed.
4. Make sure that
the room
temperature is
within operating
specifications.