Table 10. System x3690 X5 IMM error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192," on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service
technician.
Event ID
Message
806f0a0c-2589xxxx
An Over-Temperature Condition has
been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
81070608-1405xxxx
Sensor VRD 3.3V has deasserted the
transition to non-recoverable
81070608-0a01xxxx
Sensor PS n 12V OC has deasserted
81070608-0a02xxxx
the transition to non-recoverable
81070608-0a03xxxx
81070608-0a04xxxx
81070608-0a01xxxx
Sensor PS n 12V OV has deasserted
81070608-0a02xxxx
the transition to non-recoverable (n =
81070608-0a03xxxx
power supply number)
81070608-0a04xxxx
81070208-0a01xxxx
Sensor PS n Therm has transitioned to
81070208-0a02xxxx
a less severe state from critical (n =
81070208-0a03xxxx
power supply number)
81070208-0a04xxxx
81070608-0a01xxxx
Sensor PS n VCO has deasserted the
81070608-0a02xxxx
transition to non-recoverable (n =
81070608-0a03xxxx
power supply number)
81070608-0a04xxxx
81070608-0a01xxxx
Sensor PS n 12V UV has deasserted
81070608-0a02xxxx
the transition to non-recoverable (n =
81070608-0a03xxxx
power supply number)
81070608-0a04xxxx
212
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Severity
Description
Error
Memory tray bank
3/4
:Over-temperature
condition.
Error
A VRD error is
detected.
Info
Power supply n is
normal.
Info
Power supply n is
normal.
Info
Power supply n is
normal.
Info
Power supply n is
normal.
Info
Power supply n is
normal.
Action
1. Check Retain TIPs for
known issues.
2. Check the IMM event
log for any fan or
cooling related issues or
power related issues.
3. Make sure that the
airflow at the front and
rear of the chassis is not
obstructed and that the
fillers are in place and
correctly installed.
4. Make sure that the
room temperature is
within operating
specifications.
(Trained service technician
only) Replace the system
board.
No action; informational
only.
No action; informational
only.
No action; informational
only.
No action; informational
only.
No action; informational
only.