Maintenance
Removing the Fuser Module
Replacing the Stripper Finger Assembly
Replacing the Pressure Roll Cleaning Pad Assembly
Caution
Make sure the press is powered off. Do not perform this replacement procedure with
the power on or electrical power supplied to the press. Allow the fuser to cool down for
50 minutes before performing any maintenance.
1. Perform the steps for
Removing the Fuser
2. Perform the steps for
Replacing the Stripper Finger
3. Perform the steps for
Replacing the Pressure Roll
4. To remove the Pressure Roll Cleaning Pad, use a T15 Torx driver and loosen the one
screw in the front of the press. It is not necessary to remove the screw.
5. Push the pad to the rear of the press and remove it.
6. Install the new cleaning pad. Make sure to align the locking tabs with the holes in
the frame and once the Cleaning Pad Assembly is seated, push the assembly towards
the front of the press against the screw.
7. Tighten the screw to secure the pad in place.
8. Ask the administrator to reset the High Frequency Service Item (HFSI) count for this
newly-replaced CRU component at the press Control Panel.
Related Topics:
Removing the Fuser Module
Replacing the Stripper Finger Assembly
Replacing the Pressure Roll Assembly
Installing the Fuser Module
After removing the Fuser Belt Module and removing / replacing the other fuser
components, you are ready to reinstall the existing or new Fuser Belt Module.
Note
If a different width fuser is going to be installed, remove the new fuser from its packaging.
Otherwise, you will be retrieving the fuser you removed and placed on the Holding Rack.