4-3-4-4. Pre-Reset

F3SG-SRA
F3SG-SRB
First, carry out 4-3-1. Preparing to Change Settings.
Next, click the icon below on the Top page.
The setting screen below is displayed.
No.
Function name
1
Pre-Reset function
2
Maximum number of times
F3SG-SR is blocked *2
3
Maximum period of time from
input of PRE-RESET signal to
input of RESET signal
*1. When pre-reset is enabled, the pre-reset function takes priority, so the parameters of start interlock and restart interlock are
ignored.
*2. The minimum number of times is fixed to one.
For more information on pre-reset, refer to.
It is not possible to configure the Pre-Reset function together with the Muting function. To enable settings of the Pre-
Reset function, disable the Muting function. The setting parameters are kept individually in each case that the muting
function is set enabled or disabled.
After changing the Muting function from Enable to Disable or from Disable to Enable, check the settings of these
functions again.
Affected functions: External Device Monitoring (EDM), Start Interlock, Restart Interlock, Auxiliary Output
When changing the settings is complete, confirm the settings and write the configuration to the F3SG-SR.
To enable the written configuration, refer to 4-2-7-3. Writing Configuration into Intelligent Tap.
When connecting the Intelligent Tap to a F3SG-SR/PG and trying to return the F3SG-SR/PG to [Detecting], follow step 4
of 4-1-3-2. Connection Procedure When Using USB Connector to restart the F3SG-SR/PG and Intelligent Tap, or click
the [Monitor]
F3SG-PGA-A
F3SG-PGA-L
Select Enable or Disable for the Pre-Reset function.
Select desired maximum number the F3SG-SR can
be blocked in the Pre-Reset process. The minimum
number of times is 1.
If you want to set this item to infinite, select zero.
Select desired maximum time from inputting the
PRE-RESET signal to inputting the RESET signal.
button.
Setting with SD Manager 3
F3SG-PGA-C
Description
Configurable
Initial value
value or
numerical range
Disable
Enable/Disable
*1
0 (infinite)
0 to 9 times (in
1-time
increments)
8 s
1 to 60 s (in 1s
increments)
F3SG-SR/PG
User's Manual
E
253