Intelligent Tap - Omron F3SG-PGA-A User Manual

Safety light curtain f3sg sr series multi-beam safety sensor
Hide thumbs Also See for F3SG-PGA-A:
Table of Contents

Advertisement

1-5-4. Intelligent Tap

Model
Applicable sensor
Performance Response time
Startup waiting time
Electrical
Power supply voltage (Vs)
Current consumption
Safety outputs (OSSD)/
Auxiliary output
Digital output for pin 2
(IO-Link) *
*For the DO (pin 2) of CN3
Input voltage
Overvoltage category
(IEC 60664-1)
Protective circuit
Insulation resistance
Dielectric strength
Functional
Maintenance Information
Environmental Ambient
temperature
Ambient
humidity
Degree of protection
(IEC 60529)
Vibration resistance
(IEC 61496-1)
Shock resistance
(IEC 61496-1)
Pollution degree
(IEC 60664-1)
F3SG-SR/PG Series
Output ON to OFF and OFF to ON: 44 ms max. each *
*The response time is the time interval between the changes of the states of the sensor
OSSD's and the DO (pin 2).
3 s max.
Supplied from external power source: SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
USB bus powered: 5 VDC
85 mA max. (When connecting 24 VDC power supply and IO-Link Master)
Refer to the ratings and specifications of the F3SG-SR/PG. The safety outputs and
auxiliary output of the Intelligent Tap are directly connected to those of the F3SG-SR/
PG.
See 1-5-1. F3SG-SR Series for more information.
One PNP transistor output
Load current: 100 mA max., Residual voltage: 2 V max., Leakage current: 1 mA max.
The DO is in the OFF state when the safety outputs are in the ON state. The DO is in
the ON state when the safety outputs are in the OFF state. (Regardless of the PNP/
NPN setting of the F3SG-SR)
RESET, EDM PNP
ON voltage: Vs-3 V to Vs (short circuit current: approx. 9.5 mA) *2
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 13.0 mA) *2
NPN
ON voltage: 0 to 3 V (short circuit current: approx. 13.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 9.5 mA) *2
MUTE A/B,
PNP
PRE-RESET,
ON voltage: Vs-3 V to Vs (short circuit current: approx. 4.5 mA) *2
PSDI *1
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 7.0 mA) *2
NPN
ON voltage: 0 to 3 V (short circuit current: approx. 7.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 4.5 mA) *2
*1. PSDI is only available for F3SG-SR.
*2. The Vs indicates a supply voltage value in your environment.
II
Output short-circuit protection, Output reverse polarity protection
20 M or higher (500 VDC megger)
1,000 VAC, 50/60 Hz (1 min)
Error Log
Power-ON Time
See 2-27. Maintenance Information for more information.
Operating
-30 to 55 °C (non-icing)
Storage
-30 to 70 °C
Operating
35% to 85% (non-condensing)
Storage
35% to 85%
IP65, IP67 and IP67G (Covers and cables connected with the Intelligent Tap.)
10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps for all 3 axes
100 m/s
2
, 1000 shocks for all 3 axes
3
Overview and Specifications
F39-SGIT-IL3
E
F3SG-SR/PG
29
User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sg pg seriesF3sg-pga-lF3sg-pga-c

Table of Contents