Setting with SD Manager 3
No.
5
ON/OFF threshold values
*1
6
Information assigned
7
Select unit of horizontal
axis *1
*1. Not displayed in the receiving light intensity list view.
*2. The horizontal axis indicates a level in the receiving light intensity list view.
Reduced resolution zone is displayed in the Information assigned section only when the reduced resolution is enabled.
F3SG-SR/PG
264
User's Manual
Function
Shows the ON and OFF threshold values of the F3SG-SR/PG.
This information is only shown when the [Level] view is selected for the unit of vertical axis.
Shows a function assigned to the beams. The following functions can be assigned for each
sensor model.
Functions which can be assigned for F3SG-SR
-Fixed blanking zone
-Floating blanking zone or Reduced resolution zone
-Warning zone
Functions which can be assigned for all sensor models
-Muting zone
-Designated beam output zone
Switch the unit of the horizontal axis on the chart between the number of beams and
sensor length.
Description