Muting; 2-13-1.Overview - Omron F3SG-PGA-A User Manual

Safety light curtain f3sg sr series multi-beam safety sensor
Hide thumbs Also See for F3SG-PGA-A:
Table of Contents

Advertisement

2-13. Muting

The Muting and Override functions disable the safety functions of the device. Especially setting
the Muting Time Limit parameter to infinite may cause the safety functions to be disabled for a
long time. Install the F3SG-SR/PG, muting sensor and physical barrier and configure time
settings for Muting and Override so that an operator should not enter hazardous zone when the
Muting and Override are active.
Install muting sensors so that they can distinguish between the object that is being allowed to
pass through the detection zone and a person. If the Muting function is activated by the detection
of a person, the machine may not stop operating, resulting in serious injury.
Muting lamps that indicate the state of the Muting and Override functions must be installed where
they are clearly visible to workers from all the operating positions.
Use two independent input devices for muting inputs. Failure to do so may cause the MUTING
state due to a single muting sensor's failure.
F3SG-SRA
F3SG-SRB
2-13-1. Overview
Muting function temporarily disables safety function of the F3SG-SR/PG, keeping safety outputs ON
even if beams are blocked. This makes it possible to install safety light curtains for AGV passage,
enabling both safety and productivity. When muting is active, the area beam indicator (ABI) *1 or the
TOP/BTM indicator blinks to notify people around the sensor that the safety functions are disabled.
The following three operation modes are available for the Muting function.
1. Standard Muting mode (factory default setting)
2. Exit-Only Muting mode
3. Position Detection Muting mode
*1 F3SG-SRA and F3SG-PGA-A/-L/-C are applicable.
*2 F3SG-SRB is applicable.
Refer to 2-1. Combination of Functions for more information on the use in conjunction with other functions.
The following settings are available for a beam range to be muted.
• Full zone muted (factory default setting)
• Partial zone muted
F3SG-PGA-A
F3SG-PGA-L
System Operation and Functions
F3SG-PGA-C
E
F3SG-SR/PG
77