2-14-4. Setting with Intelligent Tap
The user cannot make any changes to this function by the DIP Switch.
2-14-5. Setting with SD Manager 3
The user can make changes to the settings of this function by the SD Manager 3.
Function
Override
Override input time limit
Override time limit
It is recommended that the Position 2 of the DIP Switch be set at OFF (DIP Switch Disabled).
Setting the override time limit to infinite may cause a failure of disabling the OVERRIDE state when there is a failure of
the override input signal. Conduct risk assessment analysis thoroughly before enabling this setting.
Refer to 4-3-4-3. Muting/Override for more information on setting this function by the SD Manager 3.
3 to 6 s
T1 T1 T1 T1 T1 T1
1 s max.
Initial value
Enable
1 s
600 s
System Operation and Functions
1 s max.
T2 max.
T1: Override input time limit
T2: Override time limit
Configurable value or numerical range
Enable/Disable
0.2 to 5 s in 0.1-s increments
1 to 600 s in 1-s increments, or infinite