Performing Backup - Omron F3SG-PGA-A User Manual

Safety light curtain f3sg sr series multi-beam safety sensor
Hide thumbs Also See for F3SG-PGA-A:
Table of Contents

Advertisement

3-6-2. Performing Backup

When performing the Backup, make sure to set the DIP Switch Position 1 at OFF (Unlock)
before turning on the power. If the DIP Switch Position 1 is at ON (Lock), the Restoration
is performed, which may case the settings of the F3SG-SR/PG to be overwritten and a
person to go undetected, resulting in serious injury.
Follow the flowchart below to perform backup.
For detailed steps, refer to 3-10-2. Saving Sensor Setting to Intelligent Tap Using Backup Function.
No
Yes
Intelligent Tap IN indicator
blinks fast
To run the Intelligent Tap while being connected to the F3SG-SR/PG, you must save the F3SG-SR/
PG's settings in the Intelligent Tap by the backup operation. After performing the Backup, set the DIP
Switch Position 1 at ON (Lock) and connect the Intelligent Tap to the F3SG-SR/PG.
Backup
Power OFF
Connect Intelligent Tap to
F3SG-SR/PG
Set all DIP Switches at OFF
Power ON
Intelligent Tap IN indicator
blinks slowly
Press and hold Push Switch
for over 1 sec
Yes
Perform Backup (copying
settings from F3SG-SR/PG
to Intelligent Tap)
Backup successful?
Intelligent Tap IN indicator
blinks fast and ERR
indicator lights up
Turn OFF power and
disconnect Intelligent Tap
from sensor
Set DIP Switch Position 1
at ON (Lock)
End
Setting with Intelligent Tap
All F3SG-SR/PG indicators other than
ABI or TOP/BTM indicator blink
sequentially.
When using SD Manager 3 by connect-
ing Intelligent Tap to PC, connecting
online is not possible during slow blinking
of IN indicator. Press Push Switch to
perform Backup and then connect online
via SD Manager 3.
No
If not, settings backed up here may be
accidentally overwritten later.
E
F3SG-SR/PG
161
User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sg pg seriesF3sg-pga-lF3sg-pga-c

Table of Contents