2-10-2.Factory Default Setting; 2-10-3.Setting Change Using Intelligent Tap; 2-10-4.Setting Change Using Sd Manager - Omron F3SG-PGA-A User Manual

Safety light curtain f3sg sr series multi-beam safety sensor
Hide thumbs Also See for F3SG-PGA-A:
Table of Contents

Advertisement

x Double Break
ON
Reset switch (S1)
OFF
ON
Press position
OFF
switch (S3)
Beam state Unblocked
Blocked
ON
OSSD
OFF
ON
AUX*
2
OFF
SEQ indicator
ON
(yellow)
OFF
T1: Minimum pressing time of reset switch, configurable by 100 ms in a range of 100-500 ms
T2: Minimum break time (300 ms)
T3: Minimum unblocked time during the time from removing to feeding parts. T3 = T1
T4: Minimum break time (300 ms)
T5: Minimum pressing time of press position switch. T5 = T1
T6: Wait time until double break is complete (30 s or less)
*1. When the machine is stopped by unintended block in the middle of pressing of parts, operation of the reset switch (S1)
and then double dummy break are needed for reinitiation of the machine cycle.
*2. When Auxiliary Output is set to PSDI Information by the SD Manager 3.
2-10-2. Factory Default Setting
The PSDI function is set disabled.
2-10-3. Setting Change using Intelligent Tap
It is unable to change the setting of this function using the DIP Switch of the Intelligent Tap.
2-10-4. Setting Change using SD Manager 3
The following setting can be made using SD Manager 3.
Function
PSDI function
Minimum pressing time of reset switch *
* Set the minimum pressing time of the reset switch and pre-reset switch. The same minimum pressing time is applied to both
the switches.
It is recommended that the Position 2 of the DIP Switch be set at OFF (DIP Switch Disabled).
For the details of the setting change using SD Manager 3, refer to Chapter 4 Setting with SD Manager 3.
Dummy
Feeding
break
parts
T1
T2
T3
T4
min.
min.
min.
min.
以上
Initial value
Disabled
100 ms
System Operation and Functions
Removing
Feeding
Unintended
parts
parts
break
T5
T2
T3
T4
min.
min.
min.
Machine stops
T6
ON 3 times
Configurable value or numerical range
Disable/Single break/Double break
100 to 500 ms in 100-ms increments
Dummy
Dummy
break *
1
break *
1
T1
T2
T3
T4
T5
min.
min.
min.
min.
min.
Machine restarts
ON 1 time
Solid-ON
F3SG-SR/PG
User's Manual
E
69

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sg pg seriesF3sg-pga-lF3sg-pga-c

Table of Contents