2-8-2. Factory Default Setting

The start interlock and restart interlock are disabled, so the sensor operates as the auto reset mode.

2-8-3. Setting with Intelligent Tap

Auto reset or manual reset can be configured using Positions 4 and 5 of the DIP Switch on the
Intelligent Tap.
When the Manual Reset mode is configured, start Interlock and Restart Interlock are enabled.
Refer to 3-4. LED Indicators on Intelligent Tap for more information.
• Minimum pressing time of reset switch*: 100 ms (factory default setting)
* By using SD Manager 3, the time can be set by 100 ms in a range of 100 to 500 ms.
Make sure the Position 2 of the DIP Switch is set at ON (DIP Switch Enabled) to activate the settings by the DIP Switch.
Refer to Chapter 3 Setting with Intelligent Tap for more information on setting this function by the Intelligent Tap.

2-8-4. Setting with SD Manager 3

The user can make changes to the settings of this function by the SD Manager 3.
Function
Start interlock
Restart interlock
Minimum pressing time of
reset switch
* For this function, setting parameters are kept individually in each case that the muting function is set enabled or disabled. When
changing of the muting state from enabled to disabled or vice versa using SD Manager 3, confirm the setting of this function
again.
For details, refer to Considerations for enabling and disabling Muting function with SD Manager 3 of 2-1. Combination of
Functions.
It is recommended that the Position 2 of the DIP Switch be set at OFF (DIP Switch Disabled).
Refer to 4-3-2-1. Interlock/External Device Monitoring (EDM)/PSDI for more information on setting this function by the SD
Manager 3.
Initial value
When muting enabled *
Disabled
Disabled
100 ms
System Operation and Functions
When muting disabled *
Disabled
Disabled
100 ms
Configurable value or
numerical range
Enabled/disabled
Enabled/disabled
100-500 ms (by 100 ms)