Backup/Restoration; Description Of Functions - Omron F3SG-PGA-A User Manual

Safety light curtain f3sg sr series multi-beam safety sensor
Hide thumbs Also See for F3SG-PGA-A:
Table of Contents

Advertisement

Setting with Intelligent Tap

3-6. Backup/Restoration

3-6-1. Description of Functions

F3SG-SR/PG series allow easier restoration or copy of F3SG-SR/PG's settings with an Intelligent Tap.
 Backup
You can save the F3SG-SR/PG's settings to an Intelligent Tap.
 Restoration
You can write the F3SG-SR/PG's settings saved in an Intelligent Tap to the sensor.
• You can perform both Backup and Restoration without the SD Manager 3 and even when the F3SG-SR/PG is in the
cascade connection. When performing the Restoration, the sensor configuration saved in the Intelligent Tap must be
the same as the actual sensor configuration. If the sensor configuration of other than the number of beams is not the
same, perform the Backup of the connected F3SG-SR/PG and then perform the Restoration again. Refer to 3-6-3.
Performing Restoration for the conditions to perform the Restoration.
• When the power is shut down or the F3SG-SR/PG is restarted by a reset input in the middle of the Backup or the
Restoration, the Backup or the Restoration is interrupted. Start the Backup or the Restoration over again. Refer to 3-6-
2. Performing Backup for the Backup procedure and 3-6-3. Performing Restoration for the Restoration procedure.
F3SG-SR/PG
160
User's Manual